• USB to RS485 Modbus Cable
  • USB to RS485 Modbus Cable
  • USB to RS485 Modbus Cable

USB to RS485 Modbus Cable

Application: Computer, Electronic, Automobile, RF, Home Appliance, Motorcycle
Wire Core Material: USB to RS485 Modbus Cable
Industry Type: Industrial Wire Harness
Bandaging Materials: PVC Pipe
General Wiring Harness: Injection Molding Assembly Class
Signal: USB to RS485 Modbus Cable
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
USB to RS485 Modbus Cable
Shape
Custom Shape
Interface Type
as Requires
Certification
RoHS, ISO9001
Brand
Custom Cable
Transport Package
PE Bag
Specification
as pic
Trademark
Premier Cable
Origin
China
HS Code
8544421900
Production Capacity
300000 PCS/Month

Product Description

What is a Modbus gateway ?


 
Modbus gateway is to convert one Modbus protocol frame into other protocol frame.

 


For example, the data of Modbus RTU and Modbus TCP data can be converted to each other; the application development of master request and slave response can also be carried out to improve the efficiency of protocol conversion; The storage gateway replaces the host to initiate active reporting of Modbus requests.
 

 

The device is in Modbus gateway mode to ensure the Modbus conversion efficiency to discard non-Modbus data and prevent interference to the serial bus.
 

 

Several common Modbus gateways

 


The Modbus gateway mentioned below refers to Modbus RTU to Modbus TCP, and does not involve the processing of Modbus ASCII data frames. Modbus ASCII only supports transparent transmission.

 


Simple Protocol Conversion

 

The most common and common Modbus gateway function, simple protocol conversion is the most efficient Modbus gateway mode for data processing, it just extracts key fields in the data, and then encodes the extracted data with another protocol (Modbus RTUßà Modbus TCP) to send
 


Multihost Gateway

 

The multi-host gateway can only work in the TCP server mode, and can process multiple Modbus TCP host requests at the same time. The serial server receives other host requests when one host request is not completed. At this time, the serial server will perform on the RS485 bus. Arbitration output (in layman's terms, it blocks subsequent instructions).

 

Storage gateway

 

The first thing to understand is that the communication rate of the serial port is much lower than that of the network port. The host usually only processes a few registers when requesting the RTU device. The "storage gateway" is used in this working environment.
 


Configurable Gateway

 

In order to solve the problem of slow return of the first command of the "storage" gateway, a configuration gateway can be used. The configuration gateway also adopts the method of obtaining the register content of the RS485 bus slave station by querying the "storage" gateway in advance.

 

In order to solve the problem of slow return of the first command, the required register list must be configured inside the gateway in advance.

 


The difference between Modbus RTU and Modbus TCP:

 

1. Different concepts

 

MODBUS is a standard industrial control data exchange protocol, which can exchange protocol data through RTU and ASCII

 

RTU transmits data directly through binary data, while TCP transmits data in the form of TCP code by converting each byte of binary data into a fixed two-digit hexadecimal string, and then concatenating them in sequence. RTU usually uses the most

 


2. Different communication methods

 

Ethernet, the corresponding communication mode is MODBUS TCP

 

Asynchronous serial transmission (various media, such as wired RS-232-/422/485/; optical fiber, wireless, etc.), the corresponding communication mode is MODBUS RTU or MODBUSASCII. High-speed token transmission network, the corresponding communication mode is ModbusPLUS

 

Modbus RTU Cable

 

Modbus TCP Cable

 

USB to RS485 Modbus Interface Cable

 

MAX-485 TTL to RS-485 conversion Cable